Non-Wetted Electrode Electromagnetic Flow Sensors

FD-M series

Catalogs View Catalog

Main Unit, Landscape, 10 L/min, NPN FD-MZ10AYK

FD-MZ10AYK - Main Unit, Landscape, 10 L/min, NPN

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

FD-MZ10AYK*1

Type

Horizontal

Shape

Built-in amplifier

Rated flow range

0.14 - 2.60 G/min (0.50 - 10 L/min)*1

Possible display range

0.14 - 6.35 G/min (0.50 - 30 L/min)*2

Possible ranges to set

0 - 6.35 G/min (0 - 30 L/min)

Connection port

NPT3/8 (10 A)

Detectable fluids

Water or non-corrosive liquid

Conductivity of detection fluids

5 µS/cm or higher

Detection fluid temperature

0 to +85°C 32 to 185 °F (No freezing)

Pressure loss

Max. 1.45 PSI (0.01 MPa)

Display method

Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator

Display resolution

0.01/0.1 (G/min, L/min) selectable

Repeatability

0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3

Hysteresis

Variable

Response time (chatter prevention feature)

0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable

Accumulated flow unit

0.01/0.1/1/10/100 (G, L) selectable

Integration data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

Analog output

4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value

Integration reset/bank switch input/flow zero function input

Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode

Power consumption (Current consumption)

Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less, Class 2

Environmental resistance

Enclosure rating

IP65

Pressure resistance

290 PSI (2.0 MPa)

Applied pressure range

Max. 145 PSI (1.0 MPa)

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Liquid end materials

Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)

Other materials

Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

Accessory

Instruction Manual, Connector cable (2.7 m 106.3")

Weight

Approx. 865 g

*1 The rated flow range indicates recommended operating range.
*2 Can be used within the display range as well as within the rated flow range.
*3 The repeatability for FD-MZ10ATK (P)/YK (P) in the range of 5.20 to 7.50 G/min (20 to 30 L/min) is the double of the value listed in the table. The repeatability is the error of the
detection point when fluids flow repeatedly under the same conditions.