3D Interference Measurement Sensor

WI-5000 series

Catalogs View Catalog

Controller WI-5000

WI-5000 - Controller

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

WI-5000

No. of connectable sensor heads

1

No. of registration settings

Up to 1000 settings on SD Card 1 and SD Card 2 individually (depending on the capacity and configuration of the SD Card),external switching possible

No. of measurement tools

100 tools/setting (20 are intended for position adjustment)

Measurement mode

Height

Height Measurement, Height Difference Measurement, Arranged Multi-Point Height Measurement, Free Multi-Point Height Measurement, Profile Measurement, and Continuous Height Measurement

Dimension measurement

Measure Distance, Measure Width, Line/Angle, Detect Circle, and Detect Point

Auxiliary function

Calculation, Image Region Generator, Line Display, Circle Display, Point Display, and Scale Display

Interface

Control input

20 (Input terminal: 5, Parallel I/O: 15)

Control output

28 (Output terminal block: 6, Parallel I/O: 22)
Photo MOSFET*1

RS-232C

Value output and control I/O (cannot be used when PLC link using the RS-232C port is in use)

PLC-Link

Value output and control I/O using the Ethernet port or RS-232C port (cannot be used when EtherNet/IP™ is in use.
RS-232C No-protocol communication cannot be used when the RS-232C port is in use)

Ethernet

Value output and control I/O
In addition to the functions above, uploading/downloading inspection settings, various simulations, and transmission/reception/remote connection of image and other data are possible when KEYENCE's PC application software is connected.
FTP client/server function supported, VNC server function (supporting monitor screen display only on clients other than a PC), and BOOTP function supported
1000BASE-T/100BASE-TX/10BASE-T

USB

In addition to value output and control I/O, uploading/downloading inspection settings, various simulations, and transmission/reception/remote connection of image and other data are possible when KEYENCE's PC application software is connected.
Dedicated USB 2.0

EtherNet/IP™

Value I/O and control I/O using the Ethernet port (cannot be used when PLC-Link is in use)
Cyclic communication supported (up to 1436 bytes), message communication supported
Max. number of connections: 32
Conforms to Conformance test Version CT12.

Mouse

Menus can be operated with the optional dedicated mouse (OP-87506, included with the controller).

USB HDD

Image and other data can be output when a HDD (2 TB max.) is connected to the dedicated USB port (conforms to USB3.0, bus power supported: rated output 900 mA)

Monitor output

Analog RGB output XGA 1024 × 768 (24-bit color, 60 Hz)

Minimum display unit

0.1 µm, 0.001°, 0.0001 mm2, 0.00001 mm3

Display language

English/Japanese/Chinese (simplified)/Chinese (traditional)/Korean selectable (Initial language should be determined during the initial startup.)

Rating

Maximum current consumption

2.7 A

Power voltage

24 VDC ±10 %

Environmental resistance

Ambient temperature

0 to +45 °C 32 to 113 °F (DIN rail mounting), 0 to +40 °C 32 to 104 °F (bottom mounting)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 2,000 g

*1 Either positive common connecting which is compatible with NPN input devices, or negative common connecting which is compatible with PNP input devices is feasible.