3D Scanner CMM Stage VL-730

VL-730 - 3D Scanner CMM Stage

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • CSA

Specifications

Model

VL-730

Type

Stage

Controller

VL-700

Measurement unit

VL-770

Optical transmitter system

High-brightness dual projector module

Optical receiver system

Low/high magnification offset dual optical module with wide dynamic range

Light sources

Measurement light source

Blue LED

Color texture light source

LEDs in 3 colors (red, green, blue)

Captured data format

Full-color textured 3D mesh data

Repeatability (σ)

2 μm*1

Measurement accuracy

±10 μm*2

Measurement resolution

9 million points

Measurement modes

Low magnification

High speed, Normal, Fine (wide field)

High magnification

Normal, Fine (High resolution)

Measurement range

Low magnification

ø300 × H 200 mm ø11.81" × H 7.87"(wide field)

High magnification

ø70 × H 50 mm ø2.76" × H 1.97"(High resolution)

Extended measurement

Automatic rotation combined measurements

Automatic XY combined measurements

Automatic XY combined measurement range

Low magnification (2 × 2 composition)

Low magnification (3 × 1 composition)

High magnification (2 × 2 composition)

High magnification (3 × 1 composition)

Stage

Stage configuration

Motorized θ stage mechanism

Stage top panel size

ø500 mm ø19.69"

Stage rotation

360° (infinite rotation)

Stage movement range

Tilt mechanism

Up to 45°

Load capacity

50 kg 110.23 lb

Control PC

Dedicated PC specified by KEYENCE

Power supply

Power voltage

100 to 240 VAC ±10%, 50/60 Hz

Power consumption

Controller/Measurement unit: 320 VA
Stage: 80 VA

Environmental resistance

Ambient temperature range

+15 to +30°C 59.0 to 86.0°F

Ambient humidity range

20 to 80% RH (no condensation)

Weight

Controller: 3.7 kg 8.16 lb
Stage: 21.7 kg 47.84 lb
Light-blocking cover: 4.9 kg 10.80 lb
Measurement unit: 19.6 kg 43.21 lb

*1 Value when measurement is performed using the default measurement mode specified by KEYENCE and using the default standard gauge specified by KEYENCE and at an operating ambient temperature of 23°C ±1°C 73.4°F ±1.8°F
*2 In reference to ISO 10360-8; Value when measurement is performed using the default measurement mode specified by KEYENCE and using the default standard gauge specified by KEYENCE and at an operating ambient temperature of 23°C ±1°C 73.4°F ±1.8°F

Data Sheet (PDF) Other Models