Main Unit Model: GS-M51P/GS-M91P/GS-ML51P
PNP
OSSD operation | Open/close link mode |
---|---|
Interlock function | Automatic only |
EDM function | N/A |
Applicable model | Main unit |
---|---|
Hinged door, standard type | GS-M51P GS-M91P |
Sliding door, standard type | GS-ML51P |

Required | Pin | Color | Icon above | Function |
---|---|---|---|---|
|
2 | Brown | ![]() |
+24 V |
|
7 | Blue | ![]() |
0 V |
|
5 | Black | ![]() |
OSSD1 |
|
6 | White | ![]() |
OSSD2 |
|
8 | Red/black | ![]() |
Safety input 1 |
|
4 | Red/white | ![]() |
Safety input 2 |
|
1 | Gray | ![]() |
OSSD operation switching input |
3 | Light blue | ![]() |
Lock control input |
- The required wiring ensures that the unit can be operated without entering the error state.
- Independently insulate any unused wires. Do not bundle them together.