CMOS Multi-Function Analog Laser Sensor

IL series

Catalogs View Catalog

Sensor heads IL-2000

IL-2000 - Sensor heads

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

IL-2000*1

Reference distance

2000 mm 78.74"

Measurement range

1000 to 3500 mm 39.37" to 137.80"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*2
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 1400 × 7000 µm

Linearity

±0.16% of F.S. (1000 to 3500 mm 39.37" to 137.80")*3*4

Repeatability

100 µm*5

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.016% of F.S./°C*6

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 10,000 lux*7

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 350 g

*1 Amplifiers purchased before August 8th, 2012 cannot be used.
*2 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*3 Value when measuring the KEYENCE standard target (white diffuse object).
*4 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75" IL-2000: +1000 to -1500 mm 39.37" to -59.05"
*5 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*6 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75"
*7 Value when the sampling rate is set to 2 ms or 5 ms.

Data Sheet (PDF) Other Models