Heavy-duty Photoelectric Sensors
PX series
Specs Heavy-duty Photoelectric Sensors PX series
Model |
PX-H71*1 |
PX-H71G*2 |
PX-H71TZ*4 |
PX-H72*1 |
PX-H72G*2 |
PX-H61 |
PX-H61G*4 |
|||
Image |
|
|
|
|
|
|
|
|||
Type |
M8 Thrubeam Standard |
M8 Thrubeam Armored |
M8 Thrubeam Hex-shaped |
M12 Thrubeam Standard |
M12 Thrubeam Armored |
M12 Reflective Standard |
M12 Reflective Armored |
|||
Light source LED |
Red 4-eleant LED |
Infrared LED |
Red 4-element LED |
|||||||
Detecting distance |
TURBO |
4 m 13.1' |
10 m 32.8' |
400 mm 15.7" |
||||||
SUPER |
6 m 19.7' |
15 m 49.2' |
600 mm 23.6" |
|||||||
ULTRA |
12 m 39.4' |
30 m 98.4' |
1200 mm 47.2" |
|||||||
MEGA |
20 m 65.6' |
40 m 131.2' |
2000 mm 78.7" |
|||||||
Detectable object |
ø4 mm ø0.16" Opaque materials |
ø7.5 mm ø0.30" |
― |
|||||||
Spot diameter |
― |
Approx. 15 x 15 mm 0.59" |
||||||||
Environmental resistance |
Enclosure rating |
IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K |
||||||||
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
|||||||||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||||||||
Case material |
Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7 |
|||||||||
Accessories |
Screw nut (SUS303) x 4, toothed washer (SUS304) x 2 |
Screw nut (SUS303) x 2, toothed washer (SUS304) x 2 |
Screw nut (SUS303) x 4, toothed washer (SUS304) x 2 |
Screw nut x 2, |
||||||
Weight |
Approx. 80 g (Including cable) |
Approx. 250 g*3 (Including cable) |
Approx. 88 g (Including cable) |
Approx. 90 g (Including cable) |
Approx. 260 g (Including cable) |
Approx. 80 g*3 (Including cable) |
Approx. 220 g*3 (Including cable) |
|||
*1 The PX-H71 and the H71TZ are available with a 10 m 32.8' cable for both transmitter and receiver. |
Model |
PX-10 |
PX-10C |
|||
Image |
|
|
|||
Type |
Cable type |
Connector type |
|||
Output |
NPN |
||||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
||||
Output selection |
LIGHT-ON/DARK-ON |
||||
Indicator lamp |
- Operation indicator:Red LED x 2, DSC orange LED x 1 |
||||
Detection mode |
Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor] |
||||
Shift function |
Variable between –1999 and 9999 |
||||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot |
||||
Control output |
NPN open-collector 40 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max. |
||||
External input |
Input time 2 ms (ON)/20 ms (OFF) min. |
― |
|||
Interference prevention |
Up to 4 units (in all power modes)*1 |
||||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2 |
|||
Power consumption |
Standard mode:50 mA max. at 24 V/55 mA max. at 12 V |
||||
Environmental resistance |
Enclosure rating |
IEC: IP67/JEM: IP67/NEMA: 4X |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
||||
Case material |
Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR |
||||
Weight |
Approx. 100 g (Including cable) |
Approx. 50 g |
|||
*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected |