Amplifier Separate Type Photoelectric Sensor
PS-N series
Specs Amplifier Separate Type Photoelectric Sensor PS-N series
Model |
PS-55*1 |
PS-55C*1 |
PS-05*1 |
PS-58*1 |
PS-52*1 |
PS-52C*1 |
PS-56*1 |
|||
Image |
|
|
|
|
|
|
|
|||
Type |
Long-range, Thrubeam |
Free-positioning, Thrubeam |
Cylindrical, Thrubeam |
Thin, small, Thrubeam |
||||||
Detecting distance |
TURBO |
4,000 mm 157.48"*2 |
- |
600 mm 23.62"*2 |
- |
|||||
FINE |
2,000 mm 78.74" |
700 mm 27.56" |
300 mm 11.81" |
|||||||
Light source |
Infrared LED |
|||||||||
Smallest detectable object |
TURBO |
2.0 dia.*3 |
- |
0.3 dia.*3 |
- |
|||||
FINE |
1.0 dia.*3 |
0.5 dia.*3 |
0.3 dia.*3 |
|||||||
Environmental resistance |
Enclosure rating |
IP64 |
IP67 |
- |
||||||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||||||||
Relative humidity |
35 to 85 % RH |
|||||||||
Weight |
Approx. 30 g (including 2-m 6.6' cable) |
|||||||||
*1 Models with a (C) come with plug-in connectors. (For other models, use the connector included with the amplifier.) |
Model |
PS-201*1 |
PS-201C*1 |
PS-202*1 |
|||
Image |
|
|
|
|||
Type |
Teflon®-sheathed, Thrubeam |
|||||
Detecting distance |
TURBO |
4,000 mm 157.48"*2 |
1,000 mm*2 |
|||
FINE |
2,000 mm 78.74" |
500 mm 19.69" |
||||
Light source |
Infrared LED |
|||||
Smallest detectable object |
TURBO |
1.2 dia.*3 |
0.5 dia.*3 |
|||
FINE |
0.8 dia.*3 |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||||
Relative humidity |
35 to 85 % RH |
|||||
Weight |
Approx. 40 g (including 2-m 6.6' cable) |
|||||
*1 Models with a (C) come with plug-in connectors. (For other models, use the connector included with the amplifier.) |
Model |
PS-45*1 |
PS-46*1 |
PS-48*1 |
PS-205*1 |
PS-206*1 |
|||
Image |
|
|
|
|
|
|||
Type |
Long-range, Reflective |
Thin, small, Reflective |
Cylindrical, Reflective |
Teflon®-sheathed, Reflective |
||||
Detecting distance |
TURBO |
400 mm*2 |
- |
400 mm 15.75"*2 |
- |
|||
FINE |
200 mm 7.87" |
100 mm 3.94" |
25 mm 0.98" |
200 mm 7.87" |
70 mm 2.76" |
|||
Light source |
Infrared LED |
Red LED |
||||||
Environmental resistance |
Enclosure rating |
IP64 |
- |
IP67 |
||||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||||||
Relative humidity |
35 to 85 % RH |
|||||||
Weight |
Approx. 30 g (including 2-m 6.6' cable) |
Approx. 40 g (including 2-m 6.6' cable) |
Approx. 60 g (including 2-m 6.6' cable) |
|||||
*1 Models with a (C) come with plug-in connectors. (For other models, use the connector included with the amplifier.) |
Model |
PS-47*1 |
PS-47C*1 |
PS-49*1 |
PS-49C*1 |
|||
Image |
|
|
|
|
|||
Type |
Definite reflective |
||||||
Detecting distance |
TURBO |
- |
|||||
FINE |
10 ± 4 mm 0.39" ±0.16" |
32 to 53 mm 1.26" to 2.09" |
|||||
Light source |
Red LED |
||||||
Environmental resistance |
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
-10 to +50 °C 14 to 122 °F (No freezing) |
||||
Relative humidity |
35 to 85 % RH |
||||||
Weight |
Approx. 30 g (including 2-m 6.6' cable) |
||||||
*1 Models with a (C) come with plug-in connectors. (For other models, use the connector included with the amplifier.) |
Model |
PS-N11N |
PS-N12N |
PS-N11CN |
PS-N12CN |
PS-N10 |
|||
Image |
|
|
|
|
|
|||
Type |
Cable |
M8 connector |
Zero line |
|||||
Output |
NPN |
- |
||||||
Main unit/Expansion unit |
Main unit |
Expansion unit |
Main unit |
Expansion unit |
||||
I/O |
Control outputs |
1 output |
None*3 |
|||||
External input |
1 input |
None |
1 input |
None |
||||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
|||||||
Timer function |
Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. |
|||||||
Control output |
NPN open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, |
― |
||||||
Number of interference prevention units |
4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) |
|||||||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||||||
External input |
Input time 2 ms (ON)/20 ms (OFF) or more*1 |
|||||||
Case size |
H 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1" |
|||||||
Unit expansion |
Up to 16 units (Up to 17 units including 1 main unit can be connected in total.) |
|||||||
Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
|||||||
Rating |
Power voltage |
24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
||||||
Power consumption |
Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V) |
|||||||
Environmental resistance |
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing)*2 |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||||||
Material |
Case |
Main unit and cover material: Polycarbonate |
||||||
Cable |
PVC |
|||||||
Weight |
Approx. 75 g |
Approx. 65 g |
Approx. 20 g |
|||||
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. |
Model |
PS-N11P |
PS-N12P |
PS-N11CP |
PS-N12CP |
|||
Image |
|
|
|
|
|||
Type |
Cable |
M8 connector |
|||||
Output |
PNP |
||||||
Main unit/Expansion unit |
Main unit |
Expansion unit |
Main unit |
Expansion unit |
|||
I/O |
Control outputs |
1 output |
|||||
External input |
1 input |
None |
1 input |
||||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
||||||
Timer function |
Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. |
||||||
Control output |
PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, |
||||||
Number of interference prevention units |
4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) |
||||||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
||||||
External input |
Input time 2 ms (ON)/20 ms (OFF) or more*1 |
||||||
Case size |
H 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1" |
||||||
Unit expansion |
Up to 16 units (Up to 17 units including 1 main unit can be connected in total.) |
||||||
Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
||||||
Rating |
Power voltage |
24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
|||||
Power consumption |
Normal: 860 mW or less (at 30V. 30 mA max. at 24 V, 35 mA max. at 12 V) |
||||||
Environmental resistance |
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing)*2 |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
||||||
Material |
Case |
Main unit and cover material: Polycarbonate |
|||||
Cable |
PVC |
||||||
Weight |
Approx. 75 g |
Approx. 65 g |
Approx. 20 g |
||||
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. |