Specs Digital Laser Sensor LV series

Model

LV-H35F*1

LV-H62F*1

Image

Type

Straight-beam coaxial

Retro-reflective

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

100 mm 3.94"

1.5 m 4.9'

TURBO

200 mm 7.87"

3.5 m 3.5'

SUPER

450 mm 17.72"

5 m 16.4'

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Case

Fluoroplastic (PFA)

O-ring

Fluororubber

Lens cover

Glass

Weight

Approx. 80 g

Approx. 100 g

*1 The cable minimum bend radius is 25 mm 0.98".

Back to top

Model

LV-21A

LV-21AP

LV-22A

LV-22AP

Image

Type

NPN output

PNP output

NPN output

PNP output

Main unit/expansion unit

Main unit

Expansion unit (1 line)

Control output

NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

Response speed

FINE : 80 µs , TURBO : 500 µs , SUPER , TURBO : 4 ms

Number of interference
preventive units

FINE : None , TURBO : 2 units , SUPER : 4 units

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Unit expansion

Up to 7 additional expansion units can be installed (8 units including the main unit),

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less

12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.)

Power consumption

1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing) *1

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit

Polycarbonate

Case

Weight

Approx. 120 g

Approx. 75 g

Approx. 120 g

*1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
When 2 to 5 units: -10 to +50 °C 14 to 122 °F
When 6 to 7 units: -10 to +45 °C 14 to 113 °F
When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

Back to top