Safety Light Curtain
GL-S series
Specs Safety Light Curtain GL-S series
Model |
GL-S08FH |
GL-S12FH |
GL-S16FH |
GL-S20FH |
|||
Image |
|
|
|
|
|||
Type |
Flat type |
||||||
Detection capability |
ø25 mm ø0.98" |
||||||
Total length |
179.5 mm 7.07" |
259.5 mm 10.22" |
339.5 mm 13.37" |
419.5 mm 16.52" |
|||
No. of beam |
8 |
12 |
16 |
20 |
|||
Detection height |
140mm 5.51" |
220mm 8.66" |
300mm 11.81" |
380mm 14.96" |
|||
Protection height |
186 mm 7.32" |
266mm 10.47" |
346mm 13.62" |
426mm 16.77" |
|||
Beam axis spacing |
20 mm 0.79" |
||||||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
||||||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
||||||
Light source |
Infrared LED (870 nm) |
||||||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
6.6 *1 |
||||
OFF→ON |
48.7 *1 *2 |
||||||
All blocked→ON |
63.1 *1 *3 |
||||||
Optical synchronization system (channel A or B) |
ON→OFF |
6.9 *1 |
7.4 *1 |
8.1 *1 |
8.8 *1 |
||
OFF→ON |
49.1 *1 *2 |
49.9 *1 *2 |
50.9 *1 *2 |
52.0 *1 *2 |
|||
All blocked→ON |
64.2 *1 *3 |
66.3 *1 *3 |
69.1 *1 *3 |
71.9 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
||||||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
||||||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
||||||
Control output (OSSD output) |
Output type |
2 transistor outputs |
|||||
Max. load current |
Max. 300 mA |
||||||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
||||||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
||||||
Leakage current |
Max. 200 µA |
||||||
Max. load capacitance |
2.2 µF |
||||||
Load wiring resistance |
Max. 2.5 Ω |
||||||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
||||||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
31*4 |
34*4 |
36*4 |
39*4 |
Receiver |
52*4 |
56*4 |
59*4 |
62*4 |
|||
When the center indicator is OFF |
Transmitter |
26*4 |
27*4 |
28*4 |
|||
Receiver |
47*4 |
48*4 |
49*4 |
50*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||||||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
||||||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
||||
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
||||||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
||||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
|||||
Overvoltage category |
II |
||||||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
||||||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||||||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
||||||
Operating relative humidity |
15 to 85 % RH (no condensation) |
||||||
Storage relative humidity |
15 to 95 % RH |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
||||||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
||||||
Material |
Main unit case |
Polyarylate |
|||||
Weight |
Transmitter |
95 g |
125 g |
155 g |
185 g |
||
Receiver |
130 g |
160 g |
190 g |
||||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. |
Model |
GL-S24FH |
GL-S28FH |
GL-S32FH |
GL-S36FH |
GL-S40FH |
|||
Image |
|
|
|
|
|
|||
Type |
Flat type |
|||||||
Detection capability |
ø25 mm ø0.98" |
|||||||
Total length |
499.5 mm 19.67" |
579.5 mm 22.81" |
659.5 mm 25.96" |
739.5 mm 29.11" |
819.5 mm 32.26" |
|||
No. of beam |
24 |
28 |
32 |
36 |
40 |
|||
Detection height |
460mm 18.11" |
540mm 21.26" |
620mm 24.41" |
700mm 27.56" |
780mm 30.71" |
|||
Protection height |
506mm 19.92" |
586mm 23.07" |
666mm 26.22" |
746mm 29.37" |
826mm 32.52" |
|||
Beam axis spacing |
20 mm 0.79" |
|||||||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||||||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||||||
Light source |
Infrared LED (870 nm) |
|||||||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
7.0 *1 |
7.4 *1 |
7.9 *1 |
8.3 *1 |
8.7 *1 |
|
OFF→ON |
49.3 *1 *2 |
50.0 *1 *2 |
50.6 *1 *2 |
51.3 *1 *2 |
51.9 *1 *2 |
|||
All blocked→ON |
64.9 *1 *3 |
66.6 *1 *3 |
68.3 *1 *3 |
70.0 *1 *3 |
71.8 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
9.5 *1 |
10.2 *1 |
10.9 *1 |
11.6 *1 |
12.3 *1 |
||
OFF→ON |
53.0 *1 *2 |
54.0 *1 *2 |
55.1 *1 *2 |
56.1 *1 *2 |
57.2 *1 *2 |
|||
All blocked→ON |
74.7 *1 *3 |
77.5 *1 *3 |
80.2 *1 *3 |
83.0 *1 *3 |
85.8 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||||||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||||||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||||||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||||||
Max. load current |
Max. 300 mA |
|||||||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||||||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||||||
Leakage current |
Max. 200 µA |
|||||||
Max. load capacitance |
2.2 µF |
|||||||
Load wiring resistance |
Max. 2.5 Ω |
|||||||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||||||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
41*4 |
44*4 |
45*4 |
48*4 |
50*4 |
Receiver |
64*4 |
67*4 |
70*4 |
73*4 |
76*4 |
|||
When the center indicator is OFF |
Transmitter |
28*4 |
29*4 |
30*4 |
||||
Receiver |
51*4 |
52*4 |
53*4 |
54*4 |
55*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||||||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||||||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|||||
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||||||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||||
Overvoltage category |
II |
|||||||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||||||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||||||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||||||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||||||
Storage relative humidity |
15 to 95 % RH |
|||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||||||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||||||
Material |
Main unit case |
Polyarylate |
||||||
Weight |
Transmitter |
220 g |
255 g |
290 g |
325 g |
360g |
||
Receiver |
225 g |
260 g |
295 g |
330 g |
365 |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. |
Model |
GL-S08SH |
GL-S12SH |
GL-S16SH |
GL-S20SH |
|||
Image |
|
|
|
|
|||
Type |
Slim type |
||||||
Detection capability |
ø25 mm ø0.98" |
||||||
Total length |
179.5 mm 7.07" |
259.5 mm 10.22" |
339.5 mm 13.37" |
419.5 mm 16.52" |
|||
No. of beam |
8 |
12 |
16 |
20 |
|||
Detection height |
140mm 5.51" |
220mm 8.66" |
300mm 11.81" |
380mm 14.96" |
|||
Protection height |
186mm 7.32" |
266mm 10.47" |
346mm 13.62" |
426mm 16.77" |
|||
Beam axis spacing |
20 mm 0.79" |
||||||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
||||||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
||||||
Light source |
Infrared LED (870 nm) |
||||||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
6.6 *1 |
||||
OFF→ON |
48.7 *1 *2 |
||||||
All blocked→ON |
63.1 *1 *3 |
||||||
Optical synchronization system (channel A or B) |
ON→OFF |
6.9 *1 |
7.4 *1 |
8.1 *1 |
8.8 *1 |
||
OFF→ON |
49.1 *1 *2 |
49.9 *1 *2 |
50.9 *1 *2 |
52.0 *1 *2 |
|||
All blocked→ON |
64.2 *1 *3 |
66.3 *1 *3 |
69.1 *1 *3 |
71.9 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
||||||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
||||||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
||||||
Control output (OSSD output) |
Output type |
2 transistor outputs |
|||||
Max. load current |
Max. 300 mA |
||||||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
||||||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
||||||
Leakage current |
Max. 200 µA |
||||||
Max. load capacitance |
2.2 µF |
||||||
Load wiring resistance |
Max. 2.5 Ω |
||||||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
||||||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
31*4 |
34*4 |
36*4 |
39*4 |
Receiver |
52*4 |
56*4 |
59*4 |
62*4 |
|||
When the center indicator is OFF |
Transmitter |
26*4 |
27*4 |
28*4 |
|||
Receiver |
47*4 |
48*4 |
49*4 |
50*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||||||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
||||||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
||||
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
||||||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
||||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
|||||
Overvoltage category |
II |
||||||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
||||||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||||||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
||||||
Operating relative humidity |
15 to 85 % RH (no condensation) |
||||||
Storage relative humidity |
15 to 95 % RH |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
||||||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
||||||
Material |
Main unit case |
Polyarylate |
|||||
Weight |
Transmitter |
90 g |
110 g |
135 g |
160 g |
||
Receiver |
115 g |
140 g |
165 g |
||||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. |
Model |
GL-S24SH |
GL-S28SH |
GL-S32SH |
GL-S36SH |
GL-S40SH |
|||
Image |
|
|
|
|
|
|||
Type |
Slim type |
|||||||
Detection capability |
ø25 mm ø0.98" |
|||||||
Total length |
499.5 mm 19.67" |
579.5 mm 22.81" |
659.5 mm 25.96" |
739.5 mm 29.11" |
819.5 mm 32.26" |
|||
No. of beam |
24 |
28 |
32 |
36 |
40 |
|||
Detection height |
460mm 18.11" |
540mm 21.26" |
620mm 24.41" |
700mm 27.56" |
780mm 30.71" |
|||
Protection height |
506mm 19.92" |
586mm 23.07" |
666mm 26.22" |
746mm 29.37" |
826mm 32.52" |
|||
Beam axis spacing |
20 mm 0.79" |
|||||||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||||||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||||||
Light source |
Infrared LED (870 nm) |
|||||||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
7.0 *1 |
7.4 *1 |
7.9 *1 |
8.3 *1 |
8.7 *1 |
|
OFF→ON |
49.3 *1 *2 |
50.0 *1 *2 |
50.6 *1 *2 |
51.3 *1 *2 |
51.9 *1 *2 |
|||
All blocked→ON |
64.9 *1 *3 |
66.6 *1 *3 |
68.3 *1 *3 |
70.0 *1 *3 |
71.8 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
9.5 *1 |
10.2 *1 |
10.9 *1 |
11.6 *1 |
12.3 *1 |
||
OFF→ON |
53.0 *1 *2 |
54.0 *1 *2 |
55.1 *1 *2 |
56.1 *1 *2 |
57.2 *1 *2 |
|||
All blocked→ON |
74.7 *1 *3 |
77.5 *1 *3 |
80.2 *1 *3 |
83.0 *1 *3 |
85.8 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||||||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||||||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||||||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||||||
Max. load current |
Max. 300 mA |
|||||||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||||||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||||||
Leakage current |
Max. 200 µA |
|||||||
Max. load capacitance |
2.2 µF |
|||||||
Load wiring resistance |
Max. 2.5 Ω |
|||||||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||||||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
41*4 |
44*4 |
45*4 |
48*4 |
50*4 |
Receiver |
64*4 |
67*4 |
70*4 |
73*4 |
76*4 |
|||
When the center indicator is OFF |
Transmitter |
28*4 |
29*4 |
30*4 |
||||
Receiver |
51*4 |
52*4 |
53*4 |
54*4 |
55*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||||||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||||||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|||||
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||||||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||||
Overvoltage category |
II |
|||||||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||||||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||||||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||||||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||||||
Storage relative humidity |
15 to 95 % RH |
|||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||||||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||||||
Material |
Main unit case |
Polyarylate |
||||||
Weight |
Transmitter |
185 g |
215 g |
245 g |
275 g |
305 g |
||
Receiver |
190 g |
220 g |
250 g |
280 g |
310 g |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. |