Clamp-On Gas Flow Meter
FD-G series
Specs Clamp-On Gas Flow Meter FD-G series
Clamp-On Gas Flow Meter
Model |
FD-G25 |
FD-G50 |
FD-G80 |
FD-G125 |
FD-G200 |
|||
Image |
|
|
|
|
|
|||
Pipe size |
DN (Diameter Nominal) |
20 A, 25 A |
32 A, 40 A, 50 A |
65 A, 80 A |
100 A, 125 A |
150 A, 200 A |
||
NPS (Nominal Pipe Size) |
3/4", 1" |
1 1/4", 1 1/2", 2" |
2 1/2", 3" |
4", 5" |
6", 8" |
|||
Outer diameter of pipe |
ø25 to 29 mm 0.98" to 1.14", ø32 to 36 mm 1.26" to 1.42" |
ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44" |
ø72 to 78 mm 2.83" to 3.07", ø86 to 92 mm 3.39" to 3.62" |
ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67" |
ø163 to 171 mm 6.42" to 6.73", ø214 to 222 mm 8.43" to 8.74" |
|||
Pipe thickness |
2.0 to 4.5 mm 0.08" to 0.18" |
2.4 to 5.7 mm 0.09" to 0.22" |
2.9 to 6.3 mm 0.114" to 0.25" |
3.1 to 6.8 mm 0.122" to 0.27" |
3.5 to 8.7 mm 0.14" to 0.34" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||||||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||||||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||||||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||||||
Rated velocity of flow range |
Up to 15 m/s |
|||||||
Actual flow rate range (typical) |
m3/h |
Pipe size 20 A: 20.00 |
Pipe size 32 A: 54.00 |
Pipe size 65 A: 200.0 |
Pipe size 100 A: 470.0 |
Pipe size 150 A: 1000.0 |
||
L/min |
Pipe size 20 A: 330.0 |
Pipe size 32 A: 900.0 |
Pipe size 65 A: 3300 |
Pipe size 100 A: 7800 |
Pipe size 150 A: 17000 |
|||
CFM |
Pipe size 20 A: 12.00 |
Pipe size 32 A: 32.00 |
Pipe size 65 A: 120.00 |
Pipe size 100 A: 280.00 |
Pipe size 150 A: 600.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 20 A: 56.84 |
Pipe size 32 A: 151.58 |
Pipe size 65 A: 568.43 |
Pipe size 100 A: 1326.34 |
Pipe size 150 A: 2842.15 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 20 A: 72.06 |
Pipe size 32 A: 192.17 |
Pipe size 65 A: 720.64 |
Pipe size 100 A: 1681.49 |
Pipe size 150 A: 3603.18 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 20 A: 87.28 |
Pipe size 32 A: 232.76 |
Pipe size 65 A: 872.84 |
Pipe size 100 A: 2036.63 |
Pipe size 150 A: 4364.21 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 20 A: 102.50 |
Pipe size 32 A: 273.35 |
Pipe size 65 A: 1025.05 |
Pipe size 100 A: 2391.78 |
Pipe size 150 A: 5125.24 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||||||
Display update cycle |
Approx. 3 Hz |
|||||||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.001 CFM |
0.01 m3/h, 0.1 L/min, 0.01 CFM |
0.1 m3/h, 1 L/min, 0.01 CFM |
0.1 m3/h, 1 L/min, 0.1 CFM |
|||
Consumption/leakage amount |
0.001 m3, 1 L, 0.1 CF |
0.01 m3, 1 L, 0.1 CF |
0.01 m3, 1 L, 1 CF |
0.1 m3, 1 L, 1 CF |
||||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||||||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||||||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||||||
Zero point error |
±0.15% of F.S.*2*6 |
|||||||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||||||
Hysteresis |
Variable |
|||||||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||||||
I/O wiring connection port |
M12 4-pin connector (male) |
|||||||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||||||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||||||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||||||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||||||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||||||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||||||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||||||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||||||
Communication interface |
USB |
USB 2.0 |
||||||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||||||
Transmission rate |
100 Mbps |
|||||||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||||||
Connector |
M12 connector (female, D-code) |
|||||||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||||||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||||||
Events |
100 |
|||||||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||||||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||||||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||||||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||||||
Relative humidity |
5 to 85%RH (no condensation) |
|||||||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||||||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||||||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||||||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||||||
Mounting/damping bracket |
SUS304 |
|||||||
Weight |
Approx. 2.2 kg |
Approx. 2.7 kg |
Approx. 3.6 kg |
Approx. 2.7 kg |
Approx. 2.8 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. |
Model |
FD-G25L |
FD-G50L |
FD-G80L |
FD-G125L |
FD-G200L |
|||
Image |
|
|
|
|
|
|||
Pipe size |
DN (Diameter Nominal) |
20 A, 25 A |
32 A, 40 A, 50 A |
65 A, 80 A |
100 A, 125 A |
150 A, 200 A |
||
NPS (Nominal Pipe Size) |
3/4", 1" |
1 1/4", 1 1/2", 2" |
2 1/2", 3" |
4", 5" |
6", 8" |
|||
Outer diameter of pipe |
ø25 to 29 mm 0.98" to 1.14", ø32 to 36 mm 1.26" to 1.42" |
ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44" |
ø72 to 78 mm 2.83" to 3.07", ø86 to 92 mm 3.39" to 3.62" |
ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67" |
ø163 to 171 mm 6.42" to 6.73", ø214 to 222 mm 8.43" to 8.74" |
|||
Pipe thickness |
1.5 to 3.0 mm 0.06" to 0.118" |
1.65 to 3.5 mm 0.06" to 0.138" |
2.0 to 4.0 mm 0.08" to 0.16" |
2.1 to 5.0 mm 0.08" to 0.2" |
2.8 to 5.0 mm 0.11" to 0.2" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||||||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||||||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||||||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||||||
Rated velocity of flow range |
Up to 15 m/s |
|||||||
Actual flow rate range (typical) |
m3/h |
Pipe size 20 A: 20.00 |
Pipe size 32 A: 54.00 |
Pipe size 65 A: 200.0 |
Pipe size 100 A: 470.0 |
Pipe size 150 A: 1000.0 |
||
L/min |
Pipe size 20 A: 330.0 |
Pipe size 32 A: 900.0 |
Pipe size 65 A: 3300 |
Pipe size 100 A: 7800 |
Pipe size 150 A: 17000 |
|||
CFM |
Pipe size 20 A: 12.00 |
Pipe size 32 A: 32.00 |
Pipe size 65 A: 120.00 |
Pipe size 100 A: 280.00 |
Pipe size 150 A: 600.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 20 A: 56.84 |
Pipe size 32 A: 151.58 |
Pipe size 65 A: 568.43 |
Pipe size 100 A: 1326.34 |
Pipe size 150 A: 2842.15 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 20 A: 72.06 |
Pipe size 32 A: 192.17 |
Pipe size 65 A: 720.64 |
Pipe size 100 A: 1681.49 |
Pipe size 150 A: 3603.18 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 20 A: 87.28 |
Pipe size 32 A: 232.76 |
Pipe size 65 A: 872.84 |
Pipe size 100 A: 2036.63 |
Pipe size 150 A: 4364.21 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 20 A: 102.50 |
Pipe size 32 A: 273.35 |
Pipe size 65 A: 1025.05 |
Pipe size 100 A: 2391.78 |
Pipe size 150 A: 5125.24 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||||||
Display update cycle |
Approx. 3 Hz |
|||||||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.001 CFM |
0.01 m3/h, 0.1 L/min, 0.01 CFM |
0.1 m3/h, 1 L/min, 0.01 CFM |
0.1 m3/h, 1 L/min, 0.1 CFM |
|||
Consumption/leakage amount |
0.001 m3, 1 L, 0.1 CF |
0.01 m3, 1 L, 0.1 CF |
0.01 m3, 1 L, 1 CF |
0.1 m3, 1 L, 1 CF |
||||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||||||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||||||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||||||
Zero point error |
±0.15% of F.S.*2*6 |
|||||||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||||||
Hysteresis |
Variable |
|||||||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||||||
I/O wiring connection port |
M12 4-pin connector (male) |
|||||||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||||||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||||||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||||||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||||||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||||||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||||||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||||||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||||||
Communication interface |
USB |
USB 2.0 |
||||||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||||||
Transmission rate |
100 Mbps |
|||||||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||||||
Connector |
M12 connector (female, D-code) |
|||||||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||||||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||||||
Events |
100 |
|||||||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||||||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||||||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||||||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||||||
Relative humidity |
5 to 85%RH (no condensation) |
|||||||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||||||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||||||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||||||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||||||
Mounting/damping bracket |
SUS304 |
|||||||
Weight |
Approx. 2.2 kg |
Approx. 2.7 kg |
Approx. 3.6 kg |
Approx. 2.7 kg |
Approx. 2.8 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. |