High-speed optical micrometer
LS-9000 series
Specs High-speed optical micrometer LS-9000 series
Head: Standard model/small-diameter model
Model |
LS-9006M*1 |
LS-9006*1 |
LS-9030M*1 |
LS-9030*1 |
|||
Image |
|
|
|
|
|||
Type |
Head: Small-diameter model |
Head: Standard model |
|||||
Measurement range |
0.04 mm (0.01 mm) to 6 mm 0.001" (0.0004") to 0.24" |
0.3 mm (0.08 mm) to 30 mm 0.01" (0.003") to 1.18" |
|||||
Smallest detectable object |
0.04 mm (0.01 mm) 0.001" (0.0004") |
0.3 mm (0.08 mm) 0.01" (0.003") |
|||||
Transmitter/receiver distance |
60 ±5 mm 2.36" ±0.2" |
160 ±40 mm 6.3" ±1.57" |
|||||
Repeatability |
±0.03 µm*2 |
±0.1 µm 0.000004"*6 |
|||||
Measurement accuracy |
±0.5 µm 0.000020"*3 |
±2 µm 0.000079"*7 |
|||||
Sampling cycle |
16,000 samples/sec.*4 |
||||||
Transmitter/receiver direction and position detection |
Detection area |
4 x 5 mm 0.16" x 0.2" |
20 x 24 mm 0.79" x 0.94" |
||||
Smallest detectable object |
0.04 mm 0.001" |
0.3 mm 0.01" |
|||||
Repeatability |
±0.02 mm 0.0008"*5 |
±0.2 mm 0.01"*8 |
|||||
Sampling cycle |
4,000 samples/sec. |
||||||
Light source |
InGaN green LED |
||||||
Monitor camera |
Provided |
Not provided |
Provided |
Not provided |
|||
Environmental resistance |
Enclosure rating |
IP67 (including connector) |
|||||
Ambient light |
Incandescent lamp/Fluorescent lamp: 3,000 lux or lower |
||||||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||||||
Relative humidity |
20 to 85 % RH (No condensation) |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
||||||
Shock resistance |
15 G/6 ms |
||||||
Material |
Aluminum |
||||||
Weight |
Transmitter: Approx. 130 g |
Transmitter: Approx. 130 g |
Transmitter: Approx. 440 g |
Transmitter: Approx. 440 g |
|||
*1 The values in brackets are measured in ultra-thin mode. For details on the accuracy of ultra-thin mode, contact the nearest KEYENCE office. |
Head: 2-axis standard model/2-axis small-diameter model
Model |
LS-9006D |
LS-9030D |
|||
Image |
|
|
|||
Type |
Head: 2-axis small-diameter model |
Head: 2-axis standard model |
|||
Measurement range |
ø0.04 mm to ø6 mm ø0.001" to ø0.24" |
ø0.3 mm to ø30 mm ø0.01" to ø1.18" |
|||
Smallest detectable object |
0.04 mm 0.001" |
0.3 mm 0.01" |
|||
Repeatability |
±0.03 µm*1 |
±0.1 µm 0.000004"*4 |
|||
Measurement accuracy |
±0.5 µm 0.000020"*2 |
±2 µm 0.000079"*5 |
|||
Sampling cycle |
16,000 samples/sec.*3 |
||||
Light source |
InGaN green LED |
||||
Monitor camera |
Not provided |
||||
Environmental resistance |
Enclosure rating |
IP67 (including connector part) |
|||
Ambient light |
Incandescent lamp/Fluorescent lamp: 3,000 lux or lower |
||||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||||
Relative humidity |
20 to 85 % RH (No condensation) |
||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
||||
Shock resistance |
15 G/6 ms |
||||
Material |
Aluminum |
||||
Weight |
Approx. 4.8 kg |
Approx. 9 kg |
|||
*1 A ±2σ margin of error when measuring a ø1.0 mm ø0.04" rod in the center of the measurement area using outer diameter mode with the average measurement number set as 2,048 times. |
Head: Large-diameter model
Model |
LS-9120M |
|||
Image |
|
|||
Type |
Head: Large-diameter model |
|||
Measurement range |
0.8 mm to 120 mm 0.03" to 4.72" |
|||
Smallest detectable object |
0.8 mm 0.03" |
|||
Transmitter/receiver distance |
400 ±100 mm 15.75" ±3.94" |
|||
Repeatability |
±0.3 µm 0.000012"*1 |
|||
Measurement accuracy |
±8 µm 0.000315"*2 |
|||
Sampling cycle |
16,000 samples/sec. |
|||
Light source |
InGaN green LED |
|||
Monitor camera |
Provided |
|||
Environmental resistance |
Enclosure rating |
IP67 (including connector) |
||
Ambient light |
Incandescent lamp/Fluorescent lamp: 3,000 lux or lower |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
15 G/6 ms |
|||
Material |
Aluminum |
|||
Weight |
Transmitter: Approx. 1,800 g, Receiver: Approx. 2,800 g, Base: Approx. 1,600 g |
|||
*1 A ±2σ margin of error when measuring a ø40 mm ø1.57" rod in the center of the measurement area using outer diameter mode with the average measurement number set as 2,048 times. |
Controller
Model |
LS-9501*1 |
LS-9501P*4 |
|||
Image |
|
|
|||
Type |
Controller: NPN output type |
Controller: PNP output type |
|||
No. of connectable sensor heads |
2 |
||||
Head compatibility |
Yes |
||||
Display |
Minimum display unit |
0.01 µm |
|||
Display range |
±99,999.99 µm to ±9,999.9 mm |
||||
LED display |
POWER ON indicator, ERROR indicator |
||||
Input terminal block |
Encoder input |
NPN/PNP open-collector output, voltage output (5 V/12 V/24 V), line-driver output |
|||
Synchronous 1, 2 input |
Non-voltage input |
Voltage input |
|||
Auto-zero 1, 2 input |
|||||
Reset 1, 2 input |
|||||
Storage trigger input |
|||||
Storage enable input |
|||||
Storage data clear input |
|||||
Statistics 1, 2 input |
|||||
Statistics clear 1, 2 input |
|||||
Program selection input |
Non-voltage input x 4 inputs |
Voltage input x 4 inputs |
|||
Output terminal |
Analog voltage output |
±10 V x 2 outputs, output impedance 100 Ω |
|||
Analog current output |
4 to 20 mA x 2 outputs, compatible load max. 350 Ω |
||||
Universal output |
NPN open-collector output x 10 outputs |
PNP open-collector output x 10 outputs |
|||
Status 1, 2 output |
NPN open-collector output |
PNP open-collector output |
|||
Total judgment output |
|||||
Memory FULL output |
|||||
Strobe 1, 2 output |
|||||
Error output |
NPN open-collector output (N.C.) |
PNP open-collector output (N.C.) |
|||
Interface |
Ethernet |
1000BASE-T/100BASE-TX*2 |
|||
USB |
USB 2.0 HI-SPEED supported (USB 1.1 Full-SPEED compatible)*2 |
||||
RS-232C |
Measured value output, control I/O, setting change, baud rate can be selected up to 115,200 bps |
||||
Display and settings panel |
LS-D1000 Max. four heads connectable |
||||
Rating |
Power voltage |
24 VDC ±10 %, including Ripple (P-P) |
|||
Current consumption |
When LS-HA100 not used: 1.0 A max. when 1 head connected; 1.4 A max. when 2 heads connected |
||||
Environmental resistance |
Ambient temperature |
When LS-HA100 not used: 0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
20 to 85 % RH (No condensation) |
||||
Weight |
Approx. 1,500 g |
||||
*1 NPN open-collector output rating: 50 mA max. (40 V max.), residual voltage of 1 V max. |
Head expansion unit
Model |
LS-HA100 |
|||
Image |
|
|||
Type |
Head expansion unit |
|||
No. of connectable sensor heads |
2 |
|||
Head compatibility |
Yes |
|||
Display |
LED display |
POWER ON indicator, head status indicator |
||
Output terminal |
Analog voltage output |
±10 V x 2 outputs, Output impedance 100 Ω |
||
Analog current output |
4 to 20 mA x 2 outputs, Compatible load max. 350 Ω |
|||
Power source |
Supplied from the controller |
|||
Environmental resistance |
Ambient temperature |
0 to +45 °C 32 to 113 °F |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
Setting Support Software
Model |
LS-H2 |
|||
Image |
|
|||
Type |
Setting and support software |
|||
Operating System |
Windows 11 Pro |
|||
Supported languages |
Japanese, English, German, Simplified Chinese, Traditional Chinese |
|||
CPU |
Core 2 Duo, 2 GHz or more |
|||
Memory capacity |
2 GB or more |
|||
L2 cache memory |
2 MB or more |
|||
Available hard disk space |
10 GB or more |
|||
Display |
XGA (1,024 x 768 pixels) or more, 256 colors or more |
|||
Interface |
Ethernet |
Ethernet 1000BASE-T/100BASE-TX*5 |
||
USB |
USB 2.0 HI-SPEED supported (USB 1.1 Full-SPEED compatible)*6 |
|||
*1 Home, Pro, and Enterprise editions are supported. |
Display and settings panel
Model |
LS-D1000 |
|||
Image |
|
|||
Type |
Display and settings panel |
|||
Display interface |
Measured value display |
Measured value display: 2 colors, 8 digits, 16 segments |
||
Program number display |
Monochrome, 2 digits, 7 segments |
|||
Position monitor display |
1D display: 2 colors, 32 levels |
|||
Display update cycle |
5 times/sec. |
|||
Operation input interface |
Numeric keypad, function key, lock key |
|||
Display and settings panel connection port |
2 |
|||
Power source |
Supplied from the controller |
|||
Rating |
Current consumption |
0.19 A or less |
||
Environmental resistance |
Enclosure rating |
IP65 (When panel attached, front surface only) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Weight |
Approx. 400 g |
BCD output unit
Model |
CB-BD100*1 |
|||
Image |
|
|||
Type |
BCD output unit |
|||
Display |
LED display |
POWER-ON LED |
||
Output terminal |
BCD output |
NPN open-collector output x 4 ports*2 |
||
Strobe output |
NPN open-collector output x 4 outputs |
|||
OUT selection output |
||||
Input terminal |
OUT selection output |
Non-voltage input x 4 inputs |
||
Power source |
Supplied from the controller |
|||
Rating |
Current consumption |
0.16 A or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Weight |
800 g |
|||
*1 Up to 1 unit can be connected to the controller. |
EtherNet/IP™ unit
Model |
CB-EP100 |
|||
Image |
|
|||
Type |
EtherNet/IP™ unit |
|||
Compatible network |
EtherNet/IP™ and displacement sensor-specific protocols (socket communication) |
|||
Ethernet |
Compliant standards |
IEEE 802.3 (10BASE-T), IEEE 802.3u (100BASE-TX) |
||
Transmission speed |
10 Mbps (10BASE-T), 100 Mbps (100BASE-TX) |
|||
Transmission media |
STP or Category 3 or higher UTP (10BASE-T), |
|||
Maximum cable length |
100 m 328.1' (Distance between the unit and Ethernet switch) |
|||
EtherNet |
Maximum number of connectable hubs |
4 hubs (10BASE-T), 2 hubs (100BASE-TX)*1 |
||
EtherNet/IP™ |
Supported functions |
Cyclic communication (Implicit messaging), |
||
Number of connections |
64 |
|||
RPI |
0.5 ms to 10,000 ms (in 0.5 ms) |
|||
Tolerable communication bandwidth for cyclic communication |
6,000 pps |
|||
Message communication |
UCMM, Class 3 |
|||
Conformance test |
Compatible with Version A9 |
|||
Rating |
Power voltage |
24 VDC ±10 %, including Ripple (P-P) |
||
Current consumption |
0.12 A or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Weight |
Approx. 470 g |
|||
*1 The number of connectable hubs is not limited when using a switching hub. |
PROFINET unit
Model |
CB-PN100 |
|||
Image |
|
|||
Type |
PROFINET unit |
|||
Compatible network |
PROFINET IO communication |
|||
Ethernet |
Compliant standards |
IEEE 802.3u*1 |
||
Transmission speed |
100 Mbps, full duplex (100BASE-TX) |
|||
Transmission media |
STP or Category 5e or higher UTP |
|||
Maximum cable length |
100 m 328.1' |
|||
PROFINET IO |
Supported functions |
Data I/O communication, Record data communication |
||
Number of connectable PROFINET IO controllers |
1 |
|||
Update Time |
2 ms to 2,048 ms |
|||
GSDML |
Version 2.25 |
|||
Conformance class |
Conformance Class A compliant |
|||
Conformance test version |
Based on Version 2.2.4 |
|||
Applicable protocol |
LLDP, DCP |
|||
Rating |
Power voltage |
24 V ±10 % (supplied from the controller unit of the laser scanner) |
||
Current consumption |
0.12 A or less |
|||
Weight |
Approx. 470 g |
|||
*1 Although this unit conforms to IEEE 802.3u and can establish 100 Mbps full duplex communication using AutoNegotiation function, it does not have AutoCrossOver and AutoPolarity functions that are normally required for the PROFINET IO standard. Select a straight or cross cable according to the Ethernet port of the device to be connected. |