AutoID Data Controller
DV-90 series
Specs AutoID Data Controller DV-90 series
Model |
DV-90NE |
DV-90PE |
|||
Image |
|
|
|||
Display power |
English |
||||
Applicable barcode reader |
SR-2000/1000/750/700/G100 Series*1, BL-1300/700/600/180/N70RKE, HR-100*2 |
||||
Preset data |
Number of registrations |
900 maximum |
|||
Backup method |
Flash ROM (rewritable 100,000 times) |
||||
I/O terminal |
Input terminals |
Number of inputs |
4 |
||
Input rating |
10 to 26 VDC, 10 mA |
||||
Maximum OFF current |
1.0 mA |
||||
Output terminals |
Number of outputs |
16 |
|||
Output |
NPN open collector |
PNP open collector |
|||
Output rating |
30 VDC, 100 mA |
||||
Leakage current (at OFF) |
0.1 mA or less |
||||
Residual voltage (at ON) |
Less than 1 V |
||||
DC output |
Number of inputs |
2 |
|||
Output rating |
24 VDC ± 10%, 250 mA maximum |
||||
Serial interface |
RS-232C port |
Communication method |
RS-232C compliant |
||
Synchronization between the transmitter and receiver |
Asynchronous |
||||
Communication speed |
600 to 115200bps |
||||
Number of inputs |
2 (PORT1, PORT2) |
||||
Data length |
7 or 8 bits |
||||
Parity |
None, even, odd |
||||
Stop bit length |
1 bit or 2 bits |
||||
USB port |
Number of inputs |
1 |
|||
Communication method |
Conforms to USB 2.0 Full Speed |
||||
Baud rate |
Fixed to 115,200 bps |
||||
RS-232C port |
Power supply for the barcode reader |
5 VDC ± 5%, 1,100 mA maximum (ambient temperature: 0 to 40°C 32 to 104°F) or 850 mA maximum (ambient temperature: 40 to 50°C 104 to 122°F) |
|||
Power output |
Power for sensor |
24 VDC ± 10%, 250 mA maximum |
|||
Rating |
Power voltage |
24 VDC ±10 % |
|||
Current consumption |
850 mA or less |
||||
Environmental resistance |
Enclosure rating |
IP65 |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||
Operating environment |
No dust or corrosive gases present |
||||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.3 mm 0.01", 55 to 500 Hz, 2 G |
||||
Weight |
Approx. 360 g |
||||
*1 To connect the SR-1000/750, the OP-87533 and the OP-87527/87528/87529 are required. To connect the SR-G100, the SR-LR1/OP-27937 are required. |